The valve is not closing when the coil is de-energized..

The valve is not closing when the coil is de-energized..

If the valve is not closing when the coil is de-energized;

1) The valve might be reverse installed towards flow
Solution : Ensure that the valve is installed by the correct flow direction according to indictor on valve's body
----------------------------------------------------------------------------------------
2) The plunger might be stucked in the tube or adherent on the orifice due to dirt or corrosion
Solution : Ensure that the inside of the core tube and plunger are clear. Use filter prior to valve if needed.
----------------------------------------------------------------------------------------
3) Pilot orifice or/and main orifice might be damaged by corrosion.
Solution : Replace with the original one
----------------------------------------------------------------------------------------
4) In the maintenance process, some components might be lack or reverse installed or assembled wrong in order.
Solution : Check it by the assembling diagram
 
 
 

0 Comments

No comments yet for this post.

Leave A Reply